Computerized Medical Imaging and Graphics
Volume 26, Issue 6 , Pages 419-428, December 2002

Vascular tree object segmentation by deskeletonization of valley courses

Department of Radiological Sciences I, University of California, Medical Sciences 1, B-140, Irvine, CA 92697, USA

Received 8 April 2002

Abstract 

In this paper, we propose a valley-course-based image segmentation technique for tree-like object delineation, as an alternative to the traditional centerline-based methods. This technique consists of valley-course extraction, skeleton pruning and deskeletonization. Valley courses, constructed from valley points that are obtained by star-pattern scanning over an image, offer a natural manner of identifying tree skeletons. Unattached segments are removed using morphological operations. A structured tree is then constructed from the skeletons by using a tree pruning/spanning algorithm. A fleshy tree-like object is obtained by a deskeletonization procedure, which consists of extracting tree boundary in vicinity of the skeletons in the original image. The tree boundary is determined by identifying paired edge points at a valley point. A derivative-free edge identification approach is proposed, which defines an edge point at a side-slope by a relative intensity drop with respect to the local background. An empirical formula using a logarithmic function of local intensity contrast offers desirable characteristics of adaptability and stability. The adaptability of edge points to the local background is attributed to the compression behavior of logarithmic function. Furthermore, stability to noise is resulted because derivative operations are not used. The segmentation technique was validated using coronary angiographic images.

Keywords:  Image segmentation, Valley courses, Edge extraction, Skeleton pruning, Tree spanning, Deskeletonization

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0895-6111(02)00037-X

Computerized Medical Imaging and Graphics
Volume 26, Issue 6 , Pages 419-428, December 2002