Computerized Medical Imaging and Graphics
Volume 33, Issue 6 , Pages 461-476, September 2009

Dynamic real-time 4D cardiac MDCT image display using GPU-accelerated volume rendering

Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario, N6A 5K8, Canada

Received 18 February 2008; received in revised form 16 March 2009; accepted 8 April 2009.

Abstract 

Intraoperative cardiac monitoring, accurate preoperative diagnosis, and surgical planning are important components of minimally-invasive cardiac therapy. Retrospective, electrocardiographically (ECG) gated, multidetector computed tomographical (MDCT), four-dimensional (3D + time), real-time, cardiac image visualization is an important tool for the surgeon in such procedure, particularly if the dynamic volumetric image can be registered to, and fused with the actual patient anatomy. The addition of stereoscopic imaging provides a more intuitive environment by adding binocular vision and depth cues to structures within the beating heart. In this paper, we describe the design and implementation of a comprehensive stereoscopic 4D cardiac image visualization and manipulation platform, based on the opacity density radiation model, which exploits the power of modern graphics processing units (GPUs) in the rendering pipeline. In addition, we present a new algorithm to synchronize the phases of the dynamic heart to clinical ECG signals, and to calculate and compensate for latencies in the visualization pipeline. A dynamic multiresolution display is implemented to enable the interactive selection and emphasis of volume of interest (VOI) within the entire contextual cardiac volume and to enhance performance, and a novel color and opacity adjustment algorithm is designed to increase the uniformity of the rendered multiresolution image of heart. Our system provides a visualization environment superior to noninteractive software-based implementations, but with a rendering speed that is comparable to traditional, but inferior quality, volume rendering approaches based on texture mapping. This retrospective ECG-gated dynamic cardiac display system can provide real-time feedback regarding the suspected pathology, function, and structural defects, as well as anatomical information such as chamber volume and morphology.

Keywords: Real-time, 4D volume rendering, Retrospective electrocardiographic (ECG) gating, Graphics processing units (GPUs), Stereoscopic rendering, Optical density radiation model, Ray-casting, Volume of interest (VOI), Dynamic multiresolution, Image-guided therapy, Cardiac intervention

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0895-6111(09)00043-3

doi:10.1016/j.compmedimag.2009.04.002

Computerized Medical Imaging and Graphics
Volume 33, Issue 6 , Pages 461-476, September 2009