Computerized Medical Imaging and Graphics
Volume 33, Issue 6 , Pages 461-476 , September 2009

Dynamic real-time 4D cardiac MDCT image display using GPU-accelerated volume rendering

Received 18 February 2008 ,Revised 16 March 2009 ,Accepted 8 April 2009.

References 

  1. Guiraudon GM, Jones DL, Baindridge D, Peters TM. Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasibility study. Interactive CardioVascular and Thoracic Surgery. 2007;6:603–607
  2. Linte CA, Wierzbicki M, Moore J, Little SH, Guiraudon G, Peters TM. Towards subject-specific models of the dynamic heart for image-guided mitral valve surgery. Proceedings of MICCAI. 2007;4792:94–101
  3. Wierzbicki M, Drangova M, Guiraudon G, Peters TM. Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Medical Image Analysis. 2004;8(3):387–401
  4. Linte CA, Wiles AD, Hill N, Moore J, Wedlake C, Guiraudon G, et al. An augmented reality environment for image-guidance of off-pump mitral valve implantation. Proceedings of SPIE. 2007;6509:65090N
  5. Lehmann G, Habets D, Holdsworth DW, Peters TM, Drangova M. Simulation of intra-operative 3D coronary angiography for enhanced minimally-invasive robotic cardiac intervention. Proceedings of MICCAI. 2002;2489:269–275
  6. Guiraudon GM, Jones DL, Skanes AC, Bainbridge D, Guiraudon CM, Jensen SM. En bloc exclusion of the pulmonary vein region in the pig using off pump, beating, intra-cardiac surgery: a pilot study of minimally invasive surgery for atrial fibrillation. The Annals of Thoracic Surgery. 2005;80:1417–1423
  7. Levoy M. Display of surfaces from volume data. IEEE Computer Graphics and Applications. 1988;8(3):29–37
  8. Höhne KH, Bomans M, Pommert A, Riemer M, Schiers C, Tiede U, et al. 3D visualization of tomographic volume data using the generalized voxel model. The Visual Computer. 1990;6:28–36
  9. Baek SY, Sheafor DH, Keogan MT, DeLong DM, Nelson RC. Two-dimensional multiplanar and three-dimensional volume-rendered vascular CT in pancreatic carcinoma: interobserver agreement and comparison with standard helical techniques. American Journal of Roentgenology. 2001;176(6):1467–1473
  10. Shekhar R, Zagrodsky V. Cine MPR: interactive multiplanar reformatting of four-dimensional cardiac data using hardware-accelerated texture mapping. IEEE Transactions on Information Technology in Biomedicine. 2003;7(4):384–393
  11. Lorensen WE, Harvey EC. Marching cubes: a high resolution 3D surface construction algorithm. SIGGRAPH Computer Graphics. 1987;21(4):163–169
  12. Mroz L, König A, Gröller E. Maximum intensity projection at warp speed. Computers & Graphics. 2000;24(3):343–352
  13. René WMU , Frank JL, Ben JS, Johan PC, Suresh S. Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. International Journal of Radiation Oncology Biology Physics. 2005;63(1):253–260
  14. Saito K, Saito M, Komatu S, Ohtomo K. Real-time four-dimensional imaging of the heart with multidetector row CT. RadioGraphics. 2003;23:e8
  15. Lawler LP, Ney D, Pannu HK, Fishman EK. Four-dimensional imaging of the heart based on near-isotropic MDCT data sets. AJR American Journal of Roentgenology. 2005;184(3):774–776
  16. Pharr M, Fernando R. GPU gems 2: programming techniques for high-performance graphics and general-purpose cmputation (GPU gems). Addison-Wesley Professional; 2005;
  17. Owens JD, Luebke D, Govindaraju N, Harris M, Krüger J, Lefohn AE, et al. A survey of general-purpose computation on graphics hardware. Computer Graphics Forum. 2007;26(1):80–113
  18. Zhang Q, Eagleson R, Peters TM. Real-rime visualization of 4D cardiac MR images using graphics processing units. Proceedings of IEEE International Symposium on Biomedical Imaging (ISBI). 2006;343–346
  19. Robb RA, Hanson DP. Biomedical image visualization research using the visible human datasets. Clinical Anatomy. 2006;19(3):240–253
  20. Udupa JK, Odhner D. Shell rendering. IEEE Computer Graphics and Applications. 1993;13(6):58–67
  21. Zwicker M, Pfister H, Baar JV, Gross M. EWA splatting. IEEE Transactions on Visualization and Computer Graphics. 2002;8(3):223–238
  22. Lacroute P. Analysis of a parallel volume rendering system based on the shear-warp factorization. IEEE Transactions on Visualization and Computer Graphics. 1996;2(3):218–231
  23. Cullip TJ, Neumann U. Accelerating volume reconstruction with 3D texture hardware. Technical report, University of North Carolina at Chapel Hill; 1994.
  24. Kniss J. Interactive texture-based volume rendering for large data sets. IEEE Computer Graphics and Applications. 2001;21(4):52–61
  25. Kruger J, Westermann R. Acceleration techniques for GPU-based volume rendering.. Proceedings of the 14th IEEE Visualization 2003. 2003;287–292
  26. Audigier R, Lotufo R, Falc ao A. 3D visualization to assist iterative object definition from medical images. Computerized Medical Imaging and Graphics. 2006;4(30):217–230
  27. Lei T, Udupa JK, Saha PK, Odhner D. Artery-vein separation via MRA—an image processing approach. IEEE Transactions on Medical Imaging. 2001;20(8):689–703
  28. Holmes DR, Davisb BJ, Brucec CJ, Robba RA. 3D visualization, analysis, and treatment of the prostate using trans-urethral ultrasound. Computerized Medical Imaging and Graphics. 2003;27(5):339–349
  29. Levin D, Aladl U, Germano G, Slomka P. Techniques for efficient, real-time, 3D visualization of multi-modality cardiac data using consumer graphics hardware. Computerized Medical Imaging and Graphics. 2005;29(6):463–475
  30. Lehmann H, Ecabert O, Geller D, Kiefer G, Weese J. Visualizing the beating heart: interactive direct volume rendering of high-resolution CT time series using standard PC hardware. Proceedings of SPIE. 2006;6141:614109
  31. Zhang Q, Eagleson R, Peters TM. Graphics hardware based volumetric medical dataset visualization and classification. Proceedings of SPIE. 2006;6141:61412T
  32. Wang AS, Narayan G, Kao D, Liang D. An evaluation of using real-time volumetric display of 3D ultrasound data for intracardiac catheter manipulation tasks. Volume Graphics. 2005;41–45
  33. Hastenteufel M, Yang S, Christoph C, Vetter C, Meinzer HP, Wolf I. Image-based guidance for minimally invasive surgical atrial fibrillation ablation. International Journal of Medical Robotics. 2006;2(1):60–69
  34. Sielhorst T, Bichlmeier C, Heining SM, Navab N. Depth perception—a major issue in medical AR: evaluation study by twenty surgeons. Proceedings of MICCAI. 2006;4190:364–372
  35. Maupu D, Van Horn MH, Weeks S, Bullitt E. 3D stereo interactive medical visualization. IEEE Computer Graphics and Applications. 2005;25(5):67–71
  36. Peters TM, Henri CJ, Munger P, Takahashi AM, Evans AC, Davey B, et al. Integration of stereoscopic DSA and 3D MRI for image-guided neurosurgery. Computers in Medical Imaging Graph. 1994;18:289–299
  37. Charland P, Peters TM. Optimal display conditions for quantitative analysis of stereoscopic cerebral angiograms. IEEE Transactions on Medical Imaging. 2003;15(5):648–656
  38. Dey D, Gobbi DG, Surry KJM , Slomka PJ, Peters TM. Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces: creating stereoscopic panoramas. IEEE Transactions on Medical Imaging. 2002;21:23–30
  39. Navab N, Traub N, Sielhorst J, Feuerstein T, Bichlmeier MC. Action- and workflow-driven augmented reality for computer-aided medical procedures. IEEE Computer Graphics and Applications. 2007;27(5):10–14
  40. Khamene A, Vogt S, Azar F, Sielhorst T, Sauer F, Niemann HS. Local 3D reconstruction and augmented reality visualization of free-hand ultrasound for needle biopsy procedures. Proceedings of MICCAI. 2003;2879:344–355
  41. Wang XH, Good WF. Real-time stereographic rendering and display of medical images with programmable GPUs. Computerized Medical Imaging and Graphics. 2008;32(2):118–123
  42. Blinn J. Light reflection functions for simulation of clouds and dusty surfaces. Computer Gruphics. 1982;16(3):21–29
  43. Laur D, Hanrahan P. Hierarchical splatting: a progressive refinement algorithm for volume rendering. Computer Graphics. 1991;25(4):285–288
  44. Boada I, Navazo I, Scopigno R. Multiresolution volume visualization with a texture-based octree. The Visual Computer. 2001;3(17):185–197
  45. Flohr T, Schoepf UJ, Kuettner A, Halliburton S, Bruder H, Suess C. Advances in cardiac imaging with 16-section CT-systems. Academic Radiology. 2003;10(4):386–401
  46. Flohr T, Ohnesorge B. Developments in CT. Imaging. 2006;18(2):45–61
  47. Mahesh M, Cody DD. Physics of cardiac imaging with multiple-row detector CT. RadioGraphics. 2007;27:1495–1509
  48. Kniss J, McCormick P, McPherson A, Ahrens J, Painter J, Keahey A, et al. Interactive texture-based volume rendering for large data sets. IEEE Computer Graphics Application. 2001;21:52–61
  49. Woodring J, Shen HW. Chronovolumes: a direct rendering technique for visualization time-varying data. In: Proceedings of International Workshop on Volume Graphics. 2003;p. 27–34
  50. Wang C, Garcia A, Shen HW. Interactive level-of-detail selection using image-based quality metric for large volume visualization. IEEE Transactions on Visualization and Computer Graphics. 2007;13(1):122–134
  51. Jakobs TF, Becker CR, Ohnesorge B, Flohr TG, Suess C, Schoepf UJ, et al. Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation. European Radiology. 2002;12:1081–1086
  52. Wierzbicki M, Guiraudon GM, Jones DL, Peters TM. Dose reduction for cardiac CT using a registration-based approach. Medical Physics. 2007;34(6):1884–1895

PII: S0895-6111(09)00043-3

doi: 10.1016/j.compmedimag.2009.04.002

Computerized Medical Imaging and Graphics
Volume 33, Issue 6 , Pages 461-476 , September 2009