Computerized Medical Imaging and Graphics
Volume 33, Issue 8 , Pages 593-601 , December 2009

Adaptive ultrasound imaging of the lumbar spine for guidance of epidural anesthesia

  • Denis Tran

      Affiliations

    • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
  • ,
  • King-Wei Hor

      Affiliations

    • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
  • ,
  • Victoria A. Lessoway

      Affiliations

    • Department of Ultrasound, British Columbia Women's Hospital and Health Centre, Vancouver, BC, Canada
  • ,
  • Allaudin A. Kamani

      Affiliations

    • Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada
  • ,
  • Robert N. Rohling

      Affiliations

    • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    • Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada
    • Corresponding Author InformationCorresponding author at: Dept. of Electrical and Computer Engineering, 2356 Main Mall, UBC, Vancouver, BC V6T 1Z4, Canada. Tel.: +1 604 822 2045; fax: +1 604 822 5949.

Received 10 January 2009 ,Revised 7 May 2009 ,Accepted 4 June 2009.

References 

  1. Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001;45:766–771
  2. Grau T, Leipold RW, Conradi R, Martin E, Motsch J. Ultrasound imaging facilitates localization of the epidural space during combined spinal and epidural anesthesia. Reg Anesth Pain Med. 2004;26:64–67
  3. Glossop ND, Cleary K, Banovac F . Needle tracking using the Aurora magnetic position sensor. In: Presented at: the second annual meeting of computer aided orthopedic surgery. June 19–22, 2002, Santa Fe, N.M. 2002;
  4. Fichtinger G, DeWeese TL, Patriciu A, Tanacs A, Mazilu D, Anderson JH. System for robotically assisted prostate biopsy and therapy with interactive CT guidance. Acad Radiol. 2002;9(1):60–74
  5. Wei Z, Wan G, Gardi L, Mills G, Downey D, Fenster A. Robot-assisted 3D-TRUS guided prostate brachytherapy: system integration and validation. Med Phys. 2004;31:539
  6. Grau T. Ultrasonography in the current practice of regional anaesthesia. Best Pract Res Clin Anaesthesiol. 2005;19:175–200
  7. Tran D, Kamani AA, Lessoway VA, Peterson CE, Hor KW, Rohling RN. Pre-insertion paramedian ultrasound guidance for epidural anesthesia. Anesthesia and Analgesia 2009, (in press).
  8. Willschke H, Marhofer P, Bösenberg A, Johnston S, Wanzel O, Sitzwohl C, et al. Epidural catheter placement in children: comparing a novel approach using ultrasound guidance and a standard loss-of-resistance technique. Br J Anaesth. 2006;97:200–207
  9. Kamani A, Tran D, Marzouqi F, Lessoway V, Rohling RN. Identification of the epidural space using real-time ultrasound for needle guidance in porcine subjects. In: 40th annual meeting of society for obstetric anesthesia and perinatalogy, vol. 106. April 30–May 4, 2008, Chicago, USA; Anesthesia and Analgesia. 2008;p. A18
  10. Grau T, Leipold RW, Fatehi S, Martin E, Motsch J. Real-time observation of combined spinal-epidural anaesthesia. Eur J Anaesth. 2004;21:25–31
  11. Michailovich OV, Tannenbaum A. Despeckling of medical ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Control. 2006;53:64–78
  12. York G, Kim Y. Ultrasound processing and computing: review and future directions. Ann Rev Biomed Eng. 1999;1:559–588
  13. Tran D, Kamani A, Lessoway V, Rohling R. Adaptive spatial compounding for improving ultrasound images of the epidural space. In: Proceedings of the SPIE—medical imaging 2007, vol. 6513. February 17–22, 2007, International Society for Optical Engineering, San Diego, USA. 2007;p. OW1–OW12
  14. Tran D, Kamani A, Lessoway V, Rohling RN. Adaptive spatial compounding for improving ultrasound images of the epidural space on human subjects. In: Proceedings of the SPIE—medical imaging 2008, vol. 6920. February 17–21, 2008, International Society for Optical Engineering, San Diego, USA. 2008;p. OI1–OI12
  15. Berson M, Roncin A, Pourcelot L. Compound scanning with an electrically steered beam. Ultrason Imaging. 1981;3:303–308
  16. Carpenter DA, Dadd MJ, Kossoff G. A multimode real time scanner. Ultrasound Med Biol. 1980;6:279–284
  17. Jespersen SK, Wilhjelm JE, Sillesen H. Multi-angle compound imaging. Ultrason Imaging. 1998;20:81–102
  18. Trahey GE, Smith SW, Von Ramm OT. Speckle patterns correlation with lateral aperture translation: experimental results and implications for spatial compounding. IEEE Trans Ultrason Ferroelectr Freq Control. 1986;33:257–264
  19. Jespersen SK, Wilhjelm SE, Sillesen H. In vitro spatial compound scanning for improved visualization of atherosclerosis. Ultrasound Med Biol. 2000;26:1357–1362
  20. Huber S, Wagner M, Medl M, Czerbirek H. Real-time spatial compound imaging in breast ultrasound. Ultrasound Med Biol. 2002;28:155–163
  21. Anderson ME, Soo MS, Bentley RC, Trahey GE. The detection of breast microcalcifications with medical ultrasound. J Acoust Soc Am. 1997;101:29–39
  22. Christensen D. Ultrasonic bioinstrumentation. New York: John Wiley and Sons; 1988;
  23. Groves A, Rohling R. Two dimensional spatial compounding with warping. Ultrasound Med Biol. 2004;30:929–942
  24. Wohlberg G. Digital image warping. Los Alamitos: IEEE Computer Society Press; 1990;
  25. Gersho A, Gray RA. Vector quantization and signal compression. 1st ed.. USA: Springer-Verlag; 1992;
  26. Canny J. A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell. 1986;8:679–714
  27. Wilhjelm JE, Jensen MS, Brandt T, Sahl B, Martinsen K, Jespersen SK, et al. Some imaging strategies in multi-angle spatial compounding. In: Proceeding of the IEEE ultrasonics symposium 2000, vol. 2. October 22–25, 2000, San Juan, Puerto Rico. 2000;p. 1615–1618
  28. Behar V, Nikolov M. Statistical analysis of image quality in multi-angle compound imaging. In: Proceedings of the IEEE John Vincent Atanasoff 2006 international symposium on modern computing. October 3–6, 2006, IEEE Computer Society, JVA, Washington, DC. 2006;p. 197–201
  29. Shankar PM. Speckle reduction in medical ultrasound via spatial compounding. IEEE Trans Ultrason Ferroelectr Freq Control. 1986;33(6):754–758
  30. Burlew M, Madsen E, Zagzabski J, Banjavic R, Sum S. A new ultrasound tissue-equivalent material. Radiology. 1980;134:517–520

PII: S0895-6111(09)00079-2

doi: 10.1016/j.compmedimag.2009.06.001

Computerized Medical Imaging and Graphics
Volume 33, Issue 8 , Pages 593-601 , December 2009