Computerized Medical Imaging and Graphics
Volume 33, Issue 8 , Pages 623-633 , December 2009

PET transmission tomography using a novel nonlocal MRF prior

  • Yang Chen

      Affiliations

    • The Laboratory of Image Science and Technology, Southeast University, China
    • The School of Biomedical Engineering, Southern Medical University, China
  • ,
  • Liwei Hao

      Affiliations

    • The School of Biomedical Engineering, Southern Medical University, China
  • ,
  • Xianghua Ye

      Affiliations

    • The Department of Radiation Oncology, Nanfang Hospital Affiliated to Southern Medical University, China
  • ,
  • Wufan Chen

      Affiliations

    • The School of Biomedical Engineering, Southern Medical University, China
    • Corresponding Author InformationCorresponding author at: The Laboratory of Image Science and Technology, Southeast University, Nanjing, China. Tel.: +86 13705152673.
  • ,
  • Limin Luo

      Affiliations

    • The Laboratory of Image Science and Technology, Southeast University, China
    • Corresponding Author InformationCorresponding author at: The Laboratory of Image Science and Technology, Southeast University, Nanjing, China. Tel.: +86 13705152673.
  • ,
  • Xindao Yin

      Affiliations

    • The Department of Radiology, Nanjing First Hospital Affiliated to Nanjing Medical University, China

Received 29 October 2008 ,Revised 6 May 2009 ,Accepted 24 June 2009.

References 

  1. Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Transactions on Medical Imaging. 1982;1(2):113
  2. Ollinger JM, Fessler JA. Positron emission tomography. IEEE Signal Processing Magzine. 1997;1:43
  3. Bailey D. Transmission scanning in emission tomography. European Journal of Nuclear Medicine. 1998;25(7):774
  4. Meikle S, Dahlbom M, Cherry S. Attenuation correction using count-limited transmission data in positron emission tomography. Journal of Nuclear Medicine. 1993;34:14
  5. Chatziioannou A, Dahlbom M. Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images. IEEE Transactions on Nuclear Science. 1996;43:290
  6. Fessler JA. Hybrid Poisson/polynomial objective functions for tomographic image reconstruction from transmission scans. IEEE Transactions on Image Processing. 1995;4:1439
  7. Xu M, Cutler P, Luk W. Adaptive, segmented attenuation correction for whole-body PET imaging. IEEE Transactions on Nuclear Science. 1996;43:331
  8. Smith R, Karp J, Benard F, Alavi A. A comparison of segmentation and emission subtraction for singles transmission in PET. IEEE Transactions on Nuclear Science. 1998;45:1212
  9. Ollinger JM. Maximum-likelihood reconstruction of transmission image in emission computed tomography via the EM algorithm. IEEE Transactions on Medical Imaging. 1990;13:89
  10. Lange K. Convergence of EM image reconstruction algorithms with Gibbs smoothness. IEEE Transactions on Medical Imaging. 1990;9:439
  11. Fessler JA, Ficaro E, Clinthorne N, Lange K. Grouped-coordinate ascent algorithms for penalized likelihood transmission image reconstruction. IEEE Transactions on Medical Imaging. 1997;16:166
  12. Lange K, Fessler JA. Globally convergent algorithms for maximum a posteriori transmission tomography. IEEE Transactions on Image Processing. 1995;4:1430
  13. Erdoğan H, Fessler JA. Monotonic algorithms for transmission tomography. IEEE Transactions on Medical Imaging. 1999;18:801
  14. Ahn S, Fessler JA, Blatt D, Hero AO. Convergent incremental optimization transfer algorithms: application to tomography. IEEE Transactions on Medical Imaging. 2006;25(3):283
  15. Chen Y, Gao DZ, Nie C, Luo LM, Chen WF, Yin XD, et al. Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior. Computerized Medical Imaging and Graphics. 2009;33(7):495
  16. Chen Y, Chen WF, Feng YQ, Feng QJ. Convergent Bayesian reconstruction for PET using new MRF quadratic membrane-plate hybrid multi-order prior, lecture notes in computer science. Medical Imaging and Augumented Reality. 2006;4091:309–316
  17. Johnson V, Wong WH, Hu X, Chen CT. Image restoration using Gibbs prior: boundary modeling, treatment of blurring, and selection of hyperparameter. IEEE Transactions on Pattern Analysis and Machine Intelligence. 1991;13:413
  18. Alenius S, Ruotsalainen U, Astola J. Attenuation correction for pet using count-limited transmission images reconstructed with median root prior. IEEE Transactions on Nuclear Science. 1999;46:646
  19. Yu DF, Fessler JA. Edge-preserving tomographic reconstruction with nonlocal regularization. IEEE Transactions on Medical Imaging. 2002;21:159
  20. Chen Y, Ma JH, Feng QJ, Luo LM, Shi PC, Chen WF. Nonlocal prior Bayesian tomographic reconstruction. Journal of Mathematical Imaging and Vision. 2008;30:133
  21. Buades A, Coll B, Morel JM. A nonlocal algorithm for image denoising. In: Proceedings of the IEEE international conference on computer vision pattern recognition, vol. 2. 2005;p. 60
  22. Geman S, Geman D. Stochastic relaxation, Gibbs distribution, and the Bayesian restoration of images. IEEE Transactions on Pattern Analysis and Machine Intelligence. 1984;6721:
  23. Li SZ. Markov random field modeling in image analysis. Tokyo: Springer-Verlag; 2001;
  24. Chen W, Chen M, Zhou J. Adaptively regularized constrained total least-squares image restoration. IEEE Transactions on Image Processing. 2000;9:588
  25. Fessler JA. Aspire 3.0 user’s guide: a sparse reconstruction library, Communication & Signal Processing Laboratory Technical Report No. 293, Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor; 1998.
  26. Houdson HM, Larkin RS. Accelerated image reconstruction using ordered sunsets of projection data. IEEE Transactions on Medical Imaging. 1994;13:601
  27. Fessler JA, Hero AO. Penalized maximum-likelihood image reconstruction using space-alternating generalized EM algorithms. IEEE Transactions on Image Processing. 1995;4:1417

 This research was supported by National Basic Research Program of China under grant, No. 2010CB732503.

PII: S0895-6111(09)00082-2

doi: 10.1016/j.compmedimag.2009.06.005

Computerized Medical Imaging and Graphics