Computerized Medical Imaging and Graphics
Volume 34, Issue 7 , Pages 572-578 , October 2010

High resolution lung airway cast segmentation with proper topology suitable for computational fluid dynamic simulations

  • James P. Carson

      Affiliations

    • Pacific Northwest National Laboratory, 902 Battelle Boulevard, P.O. Box 999, MSIN P7-58, Richland, WA 99352, United States
    • Corresponding Author InformationCorresponding author at: Pacific Northwest National Laboratory, Biological Monitoring and Modeling, 902 Battelle Boulevard, P.O. Box 999, MSIN P7-58, Richland, WA 99352, United States. Tel.: +1 509 371 6894; fax: +1 509 371 6978.
  • ,
  • Daniel R. Einstein

      Affiliations

    • Pacific Northwest National Laboratory, 902 Battelle Boulevard, P.O. Box 999, MSIN P7-58, Richland, WA 99352, United States
  • ,
  • Kevin R. Minard

      Affiliations

    • Pacific Northwest National Laboratory, 902 Battelle Boulevard, P.O. Box 999, MSIN P7-58, Richland, WA 99352, United States
  • ,
  • Michelle V. Fanucchi

      Affiliations

    • University of Alabama at Birmingham, 1530 3rd Ave S, Birmingham, AL 35294, United States
  • ,
  • Christopher D. Wallis

      Affiliations

    • Air Quality Research Center, University of California at Davis, One Shields Avenue, Davis, CA 95616, United States
  • ,
  • Richard A. Corley

      Affiliations

    • Pacific Northwest National Laboratory, 902 Battelle Boulevard, P.O. Box 999, MSIN P7-58, Richland, WA 99352, United States

Received 20 February 2009 ,Revised 1 December 2009 ,Accepted 10 March 2010.

References 

  1. Han X, Xu C, Braga-Neto U, Prince JL. Topology correction in brain cortex segmentation using a multiscale, graph-based algorithm. IEEE Trans Med Imag. 2002;21:109–121
  2. Shattuck DW, Leahy RM. Automated graph-based analysis and correction of cortical volume topology. IEEE Trans Med Imag. 2001;20:1167–1177
  3. Chaturvedi A, Lee Z. Three-dimensional segmentation and skeletonization to build an airway tree data structure for small animals. Phys Med Biol. 2005;50:1405–1419
  4. Nooruddin FS, Turk G. Simplification and repair of polygonal models using volumetric techniques. IEEE Trans Visual Comp Graph. 2003;9:191–205
  5. Einstein DR, Neradilak B, Pollisar N, Minard KR, Wallis C, Fanucchi M, et al. An automated self-similarity analysis of the pulmonary tree of the Sprague–Dawley rat. Anat Rec (Hoboken). 2008;291:1628–1648
  6. Perry SF, Purohit AM, Boser S, Mitchell I, Green FH. Bronchial casts of human lungs using negative pressure injection. Exp Lung Res. 2000;26:27–39
  7. Zhou QY, Ju T, Hu SM. Topology repair of solid models using skeletons. IEEE Trans Vis Comput Graph. 2007;13:675–685
  8. Palagyi K, Kuba A. A 3D 6-subiteration thinning algorithm for extracting medial lines. Pattern Recogn Lett. 1998;19:613–627
  9. Treece GM, Prager RW, Gee AH. Regularized marching tetrahedra: improved iso-surface extraction. Comp Graph. 1999;23:583–598
  10. Kuprat A, Khamayseh A, George D, Larkey L. Volume conserving smoothing for piecewise linear curves, surfaces, and triple lines. J Comput Phys. 2001;172:99–118
  11. Ju T, Zhou QY, Hu SM. Editing the topology of 3D models by sketching. San Diego: SIGGRAPH; 2007;
  12. Kuprat AP, Einstein DR. An anisotropic scale-invariant unstructured mesh generator suitable for volumetric imaging data. J Comput Phys. 2009;228(3):619–640
  13. Gemci T, Ponyavin V, Chen Y, Chen H, Collins R. Computational model of airflow in upper 17 generations of human respiratory tract. J Biomech. 2008;41:2047–2054
  14. Isaacs KK, Schlesinger RB, Martonen TB. Three-dimensional computational fluid dynamics simulations of particle deposition in the tracheobronchial tree. J Aerosol Med. 2006;19:344–352
  15. Nowak N, Kakade PP, Annapragada AV. Computational fluid dynamics simulation of airflow and aerosol deposition in human lungs. Ann Biomed Eng. 2003;31:374–390
  16. Kabilan S, Lin CL, Hoffman EA. Characteristics of airflow in a CT-based ovine lung: a numerical study. J Appl Physiol. 2007;102:1469–1482
  17. Cline HE, Dumoulin CL, Lorensen WE, Souza SP, Adams WJ. Volume rendering and connectivity algorithms for MR angiography. Magn Reson Med. 1991;18:384–394

PII: S0895-6111(10)00028-5

doi: 10.1016/j.compmedimag.2010.03.001

Computerized Medical Imaging and Graphics
Volume 34, Issue 7 , Pages 572-578 , October 2010