| |
Article Title |
Author(s) |
Type (Status) |
Available Online |
|
Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
DOI: 10.1016/j.compmedimag.2011.12.005
Abstract: In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the cor...
|
A.A. Isola,
C.T. Metz,
M. Schaap,
S. Klein,
M. Grass,
W.J. Niessen
et al.
|
Full-length article
(In Press Corrected Proof)
|
30 January 2012 |
|
3D segmentation of abdominal aorta from CT-scan and MR images
DOI: 10.1016/j.compmedimag.2011.12.001
Abstract: We designed a generic method for segmenting the aneurismal sac of an abdominal aortic aneurysm (AAA) both from multi-slice MR and CT-scan examinations. It is a semi-automatic method requirin...
|
Anthony Adam Duquette,
Pierre-Marc Jodoin,
Olivier Bouchot,
Alain Lalande
|
Full-length article
(In Press Corrected Proof)
|
18 January 2012 |
|
Modeling and visualization techniques for virtual stenting of aneurysms and stenoses
DOI: 10.1016/j.compmedimag.2011.12.002
Abstract: In this work, we present modeling and visualization techniques for virtual stenting of aneurysms and stenoses. In particular, contributions to support the computer-aided treatment of artery ...
|
Jan Egger,
Stefan Grosskopf,
Christopher Nimsky,
Tina Kapur,
Bernd Freisleben
et al.
|
Full-length article
(In Press Corrected Proof)
|
09 January 2012 |
|
An SVM-based distal lung image classification using texture descriptors
DOI: 10.1016/j.compmedimag.2011.11.001
Abstract: A novel imaging technique can now provide microscopic images of the distal lung in vivo, for which quantitative analysis tools need to be developed. In this paper, we present an image classi...
|
Chesner Désir,
Caroline Petitjean,
Laurent Heutte,
Luc Thiberville,
Mathieu Salaün
et al.
|
Full-length article
(In Press Corrected Proof)
|
19 December 2011 |
|
A fast and accurate automatic lung segmentation and volumetry method for MR data used in epidemiological studies
DOI: 10.1016/j.compmedimag.2011.10.001
Abstract: In modern epidemiological population-based studies a huge amount of magnetic resonance imaging (MRI) data is analysed. This requires reliable automatic methods for organ extraction. In the c...
|
Tetyana Ivanovska,
Katrin Hegenscheid,
Rene Laqua,
Jens-P. Kühn,
Sven Gläser,
Ralf Ewert,
Norbert Hosten,
Ralf Puls,
Henry Völzke
et al.
|
Full-length article
(In Press Corrected Proof)
|
14 November 2011 |
|
Molecular imaging of small animals with fluorescent proteins: From projection to multimodality
DOI: 10.1016/j.compmedimag.2011.09.002
Abstract: Fluorescent proteins (FPs) have been widely adopted in cell research for protein trafficking and reporter gene expression studies, as well as to study other biological processes. However, bi...
|
Xiaoquan Yang,
Hui Gong,
Jianwei Fu,
Guotao Quan,
Chuan Huang,
Qingming Luo
et al.
|
Full-length article
(In Press Corrected Proof)
|
26 October 2011 |
|
Three-dimensional elliptical reconstruction for stereoscopic magnetic resonance angiography
DOI: 10.1016/j.compmedimag.2011.08.003
Abstract: Stereoscopic MRA acquires a pair of blood vessel projections at two different viewing angles. Previously, we have developed two algorithms to reconstruct 3-D blood vessels from stereoscopic ...
|
Jan-Ray Liao,
Shye-Chorng Kuo
|
Full-length article
(In Press Corrected Proof)
|
07 September 2011 |
|
Motion correction for cellular-resolution multi-photon fluorescence microscopy imaging of awake head-restrained mice using speed embedded HMM
DOI: 10.1016/j.compmedimag.2011.08.002
Abstract: Multi-photon fluorescence microscopy (MFM) captures high-resolution fluorescence image sequences and can be used for the intact brain imaging of small animals. Recently, it has been extended...
|
Taoyi Chen,
Zhong Xue,
Changhong Wang,
Zhenshen Qu,
Kelvin K. Wong,
Stephen T.C. Wong
et al.
|
Full-length article
(In Press Corrected Proof)
|
05 September 2011 |
|
Perfusion linearity and its applications in perfusion algorithm analysis
DOI: 10.1016/j.compmedimag.2011.08.001
Abstract: Perfusion analysis computes blood flow parameters (blood volume, blood flow, and mean transit time) from the observed flow of a contrast agent passing through the patient's vascular system. ...
|
Oleg S. Pianykh
|
Full-length article
(In Press Corrected Proof)
|
26 August 2011 |
|
Building a reference multimedia database for interstitial lung diseases
DOI: 10.1016/j.compmedimag.2011.07.003
Abstract: This paper describes the methodology used to create a multimedia collection of cases with interstitial lung diseases (ILDs) at the University Hospitals of Geneva. The dataset contains high-r...
|
Adrien Depeursinge,
Alejandro Vargas,
Alexandra Platon,
Antoine Geissbuhler,
Pierre-Alexandre Poletti,
Henning Müller
et al.
|
Full-length article
(In Press Corrected Proof)
|
01 August 2011 |
|
Ultrasound intima–media segmentation using Hough transform and dual snake model
DOI: 10.1016/j.compmedimag.2011.06.007
Abstract: Common carotid artery intima–media thickness (IMT), which is usually measured upon ultrasound images, is an important indicator to cardiovascular diseases. This paper proposes a snake model ...
|
Xiangyang Xu,
Yuan Zhou,
Xinyao Cheng,
Enmin Song,
Guokuan Li
et al.
|
Full-length article
(In Press Corrected Proof)
|
08 July 2011 |
|
Active cardiac model and its application on structure detection from early fetal ultrasound sequences
DOI: 10.1016/j.compmedimag.2011.04.002
Abstract: The structure of an early fetal heart provides vital information for the diagnosis of fetus defects. However, early fetal hearts are difficult to detect due to their relatively small size an...
|
Yinhui Deng,
Yuanyuan Wang,
Yuzhong Shen,
Ping Chen
|
Full-length article
(In Press Corrected Proof)
|
30 May 2011 |